flexible liquid storage tanks
HomeCompany informationContactPicture galleryÁtváltás magyar nyelvre

Flexible liquid storage tanks

Air domes
Tents with aluminium frame construction
Tensile membranes,Stadium covers
Flexible liquid storage tanks


DESCRIPTION OF THE PRODUCT RANGE

flexible liquid storage tanks

This description intends to present solutions for the modern storage of liquids and gases.

Our tarpaulin confectioning company, GRABOPLAN is able to present reference projects completed 25-30 years ago as the manufacturer of liquid storage reservoirs and basin lining of various sizes and types. The high standard of our professionals' training, our plants and machinery as well as leading-edge technological solutions in addition to world-class raw materials make it possible for us to satisfy the most demanding needs of our customers.

Perfectly water-tight liquid storage reservoirs and basin lining are suitable to store hydrant water, irrigation water, fertilisers, liquid manure, waste water and other industrial and agricultural liquids containing materials hazardous detrimental to the environment, with a capacity of 1 m3 up to several times 10,000 m3.
We produce our tarpaulins with the latest high-frequency welding appliances and we assume excellent quality (ISO 9002) and long service life (at least 20 years). Our tailor-made products are easy to install and the above-ground models can easily be mobilised.

The tarpaulin materials with insulation features and, with some models, assuming the role of support frame have type approval and the Application Permit of the National Water Management Directorate for use in water management.
In addition to traditional ground basin lining, we have developed above-ground flexible liquid storage reservoirs with no separate support frame (up to 100 m3) and gas storage facilities. Such products are suitable for the storage of hydrant water, fertilisers, suspension or the temporary storage of oil.

We hope that the utilisation of products in the booklet will help your work. We encourage you to use our products wherever these reservoirs provide a solution for your liquid storage needs.




LINING FOR LIQUID MANURE STORAGE BASINS


Insulation is made of 1.5 mm thick, water-tight and long service life industrial-grade tarpaulins of high tensile strength with polyester fabric backing and PVC spread on both sides.

The insulation materials have the Application Permit of the National Water Management Directorate for use in water management and the are listed in the asset subsidy catalogue of the Ministry of Agriculture and Regional Development.

Key advantages of using tarpaulin material produced by our company:

perfectly water-tight
open or closed design
can be installed with no size limitations
will keep its quality features between -30 and +70 °C
long service life of no less than 20 years
ISO 9001:2000 Quality Assurance System
factory production conditions
more than 30 years of experience in production, with references
production lead time is independent from weather conditions
easy to install, no need for maintenance
damages can be repaired on site with adhesive binding or welding

We deliver reservoir lining produced to size and provide lead technician or entire installation as required by Client.



flexible liquid storage tanksOPEN AND CLOSED HYDRANT WATER RESERVOIRS IN GROUND BASINS
Technical description


APPLICATION: for the storage of required and specified volume of hydrant water on the premises of agricultural or industrial plants

PARTS OF THE RESERVOIR
Insulating tarpaulin: 0.70 mm thick, water-tight black industrial-grade tarpaulin of a specific weight of 850 g/m2 with polyester fabric backing and PVC spread on both sides, which material and the liquid storage basins made from it have the Application Permit of the National Water Management Directorate for use in water management. The expected service life is 15 years.
Discharge pipe: A discharge pipe is to be provided for each commenced 100 m3 of hydrant water reservoirs. Steel or plastic pipes of a minimum internal diameter of DN100 must be provided for the discharge of hydrant water.

The external end of the pipe must be provided with a DN100 type A discharge branch clamp and cap clamp, while the lower end in the reservoir must be provided with a strainer basket.

The pipe is connected to the reservoir via a flanged pipe end produced from tarpaulin on the site.

Water in the pipe should be protected from frost. The design of the reservoir should therefore ensure that the water level in the pipe stays below frost line. The distance of pipes is at least 5 m in the case of several discharge pipes.

Filling branch: The filling branch is located at the top of the reservoir with DN52 branch clamp and cap clamp, through which the reservoir can be filled up.

Floater: The floater is located in the middle of the reservoir filled with foam and wrapped in tarpaulin. This accessory ensures that the middle of the reservoir is at the highest level and storm water can leave towards the edges of the reservoir.

Manhole: A water-tight zip fastener built in the top of the reservoir, providing access to the inside of the reservoir at the time of installation and maintenance later.

Design: The shape of the reservoir is designed and the cutting template is produced with a computer aided process, while confectioning is accomplished with high-frequency welding.

Layout options: Square, rectangle or circle. Recommended reservoir sizes as a function of hydrant water to be stored are shown in the attached drawings.

Ground basin: Stipulations of the MSZ 15003 Standard "Design specifications for the limitation, support and dewatering of trenches" and MSZ 15032 Standard "Process of earthworks".

Installation: The tarpaulin prepared for installation can be installed onto a smooth compacted ground basin free of sharp and cutting contamination. The installation of geo-textile or sand bedding is recommended for the protection of tarpaulin.
The tarpaulin of the open reservoir is fastened by earth beams, while the closed reservoirs are fastened by crooks and rope.
The drainage of storm water flowing from larger closed reservoirs is provided by way of drain piping of the slope under the tarpaulin or other manners such as breaking through the earth filling.

Cleaning, maintenance: The surface of the reservoir does not require washing or cleaning, though large physical contamination must be remove. It is recommended to rinse the surface of the reservoir with clear water 1 or 2 times a year. The tarpaulin must be protected from strong mechanical strains and pierced/cut damages.

Repair: Smaller (3-4 cm) damages can be repaired with the repair set supplied with the reservoir, while large size damages are repaired by the manufacturer's technicians.


Reference projects:
Open reservoirs: 400  m3 Pannon Gabona Rt. Csorna 1996
400  m3 Hód-Mezőgazda Rt. Hódmezővásárhely 1997
200  m3 KEVE Rt. Tabajd 1999
150  m3 Classens Kft. Somogyszob 1999
100  m3 HIRSCHLER Sopron 2000
400  m3 Interfa Furniture Kft. Szany 2001
200  m3 Leier Kft. Ács 2002
Closed reservoirs: 150  m3 GAÁL Sponge Processing Plant Halastó 1999
200  m3 MASPED Rt. Dunakeszi 2000
250  m3 Vasi Warehouse Kft. Csénye 2000
250  m3 FIORÁCS Kft. Ács 2001
600  m3 VELUX Fertőd 2002
155  m3 MAPEI Kft. Sóskút 2002
100  m3 Kunság Fenster Kft. Jászszentlászló 2002